GC Nut/Ferrule Compatibility Table
- Share:
Agilent GCs
Shimadzu GCs
Thermo GCs
Varian GCs
PerkinElmer GCs
SRI and Buck GCs
Agilent GC Nut and Ferrule Compatibility
Available Ferrule Cat.# |
Description |
Compatible Nut Cat.# |
|||||
![]() |
22214, 20200, 20227, 20211, 20229, 27062, 27063 | Standard Ferrules (Fit ≤ 0.28 mm ID Fused Silica Columns) |
Capillary Column Nuts |
Finger-Tight Capillary Column Nuts |
Finger-Tight Capillary Column Nuts |
Extended Capillary Column Nuts |
Hot Swap Capillary Column Nuts |
Standard Ferrules & Standard Ferrules |
|||||||
22216, 20202, 20224, 20213, 20230, 27067, 27068 |
Standard Ferrules |
||||||
20232, 27066 | Standard Ferrules (Fit 0.28 mm ID MXT Columns) |
||||||
Capillary Ferrules (includes all the above) | Capillary Ferrules for 1/16" Compression-Type Fittings |
||||||
![]() |
20250, 20251, 20238, 20239, 27070, 27071 | Compact Ferrules (Fit ≤ 0.28 mm ID Fused Silica Columns) |
Capillary Column Nuts |
Finger-Tight Capillary Column Nuts |
Finger-Tight Capillary Column Nuts |
Extended Capillary Column Nuts |
Hot Swap Capillary Column Nuts |
21007, 21008, 20248, 20249, 27072, 27073 |
Compact Ferrules |
||||||
20252, 20253, 20263, 20264, 27074, 27075 |
Compact Ferrules |
||||||
21059, 21061 | Compact Ferrules for Micropacked Columns |
||||||
Need more help finding the correct ferrule to install your column in an Agilent GC? |
Shimadzu GC Nut and Ferrule Compatibility
Available Ferrule Cat.# |
Description |
Available Inlet Adaptor and Compatible Nut |
||
![]() |
22214, 20200, 20227, 20211, 20229, 27062, 27063 | Standard Ferrules (Fit ≤ 0.28 mm ID Fused Silica Columns) |
Inlet Adaptor (for Shimadzu 17A, 2010, 2014, and 2030 GCs) |
Hot Swap Column Nut |
Standard Ferrules & Standard Ferrules |
||||
22216, 20202, 20224, 20213, 20230, 27067, 27068 |
Standard Ferrules |
|||
20232, 27066 | Standard Ferrules (Fit 0.28 mm ID MXT Columns) |
|||
Capillary Ferrules (includes all the above) | Capillary Ferrules for 1/16" Compression-Type Fittings |
|||
![]() |
5 mm Ferrules for Use with Packed Columns (for Shimadzu 17A GCs) |
N/A |
N/A |
|
![]() |
Fit ≤ 0.28 mm ID Fused Silica Columns |
![]() Slot |
![]() No Slot |
|
Fit 0.32 mm ID Fused Silica Columns |
||||
Fit 0.45/0.53 mm ID Fused Silica Columns |
||||
Need more help finding the correct ferrule to install your column in a Shimadzu GC? |
Thermo GC Nut and Ferrule Compatibility
Available Ferrule Cat.# |
Description |
Compatible Nut Cat.# |
||||
![]() |
Standard Ferrules |
Adaptor For Capillary Column on Detector Base |
Adaptor for Capillary Column |
Siltek-Treated Adaptor for Capillary Column on Split/Splitless Injector |
Stainless Steel 1/16" Nut |
|
Standard Ferrules |
||||||
Standard Ferrules |
||||||
Standard Ferrules |
||||||
Capillary Ferrules |
Capillary Ferrules for 1/16" Compression-Type Fittings |
|||||
![]() |
Ferrules for Thermo Scientific GCs |
Adaptor for Capillary Column on Detector Base |
Adaptor for Capillary Column on Split/Splitless Injector |
Siltek-Treated Adaptor for Capillary Column on Split/Splitless Injector |
Fixing Nut for Capillary Column for Split/Splitless Injector on Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL |
|
Ferrules for Thermo Scientific GCs |
||||||
Ferrules for Thermo Scientific GCs |
||||||
Need more help finding the correct ferrule to install your column in a Thermo Scientific GC? |
Varian GC Nut and Ferrule Compatibility
Available Ferrule Cat.# |
Description |
Compatible Nut Cat.# |
|
![]() |
22214, 20200, 20227, 20211, 20229, 27062, 27063 | Standard Ferrules (Fit ≤ 0.28 mm ID Fused Silica Columns) |
![]() Capillary Nuts |
22215, 20201, 20228, 20212, 20231, 27064, 27065 | Standard Ferrules (Fit 0.32 mm ID Fused Silica Columns) & Standard Ferrules (Fit 0.25/0.32 mm ID MXT Columns) |
||
22216, 20202, 20224, 20213, 20230, 27067, 27068 | Standard Ferrules (Fit 0.45/0.53 mm ID Fused Silica Columns) & Standard Ferrules (Fit 0.53 mm ID MXT Columns) |
||
20232, 27066 | Standard Ferrules (Fit 0.28 mm ID MXT Columns) | ||
Capillary Ferrules (includes all the above) | Capillary Ferrules for 1/16" Compression-Type Fittings | ||
Need more help finding the correct ferrule to install your column in a Bruker/Varian GC? |
PerkinElmer GC Nut and Ferrule Compatibility
Available Ferrule Cat.# |
Description |
Compatible Nut Cat.# |
|
![]() |
20211, 20229, 27062, 27063 | Standard Ferrules for PerkinElmer GCs (Fit ≤ 0.28 mm ID Fused Silica Columns) | No compatible nut for PerkinElmer systems. |
20212, 20231, 27064, 27065 | Standard Ferrules for PerkinElmer GCs (Fit 0.32 mm ID Fused Silica Columns) & Standard Ferrules for PerkinElmer GCs (Fit 0.25/0.32 mm ID MXT Columns) |
||
20213, 20230, 27067, 27068 | Standard Ferrules for PerkinElmer GCs (Fit 0.45/0.53 mm ID Fused Silica Columns) & Standard Ferrules for PerkinElmer GCs (Fit 0.53 mm ID MXT Columns) |
||
Need more help finding the correct ferrule to install your column in a PerkinElmer GC? |
SRI and Buck GC Nut and Ferrule Compatibility
Available Ferrule Cat.# |
Description |
Compatible Nut Cat.# |
||
![]() |
20205, 20254, 27079 | Ferrules for SRI & Buck Scientific GCs (Fit 0.25/0.32 mm ID Fused Silica Columns) |
Brass |
![]() Stainless Steel |
20205, 20255, 27080 | Ferrules for SRI & Buck Scientific GCs (Fit 0.32 mm ID Fused Silica Columns) & Ferrules for SRI and Buck Scientific GCs (Fit 0.25/0.32 mm ID MXT Columns) |
|||
20206, 20215, 27081 | Ferrules for SRI & Buck Scientific GCs (Fit 0.45/0.53 mm ID Fused Silica Columns) & Ferrules for SRI and Buck Scientific GCs (Fit 0.53 mm ID MXT Columns) |