MXT Capillary Column Coiling Configurations

  • Share:

Restek MXT capillary columns come in the standard configurations given on each product web page. However, they can also be ordered in a variety of other configurations. To order an MXT column in one of the following configurations, use the appropriate suffix from the table below. For example, use catalog number 71811-274 to order an MXT-1 column wound to 2.0" ID without cage. When ordering, enter the base catalog number in your cart and then add the suffix under Special Instructions.

Please note that MXT PLOT columns are only available in the standard 7"-diameter, 11-pin cage configuration and the “-273” configuration.

All OD's provided are estimates and can vary based on the tubing ID and column length.

Catalog Number Suffix

MXT Coiling Description

-274

2.0" ID without cage

-2740

2.0" ID banded with copper wire

-273

2.75" ID/3.5" OD without cage (fits SRI GCs)

-2730

2.75" ID/3.5" OD banded with copper wire (fits SRI GCs)

-2731

2.75" ID/3.5" OD without cage, 18" leads (fits SRI GCs)

-2732

2.75” ID/3.5” OD without cage, 9” leads (fits SRI GCs)

-283

3.5" ID/4.0" OD without cage

-2830

3.5" ID/4.0" OD banded with copper wire

-2831

3.5” ID/4.0” OD without cage, 18” leads (fits SRI GCs)

-272

4.5" ID/5.0" OD without cage

-2720

4.5" ID/5.0" OD banded with copper wire

-6850M

5.0" ID/5.25" OD banded with copper wire

-271

6.0" ID/6.5" OD without cage

-2710

6.0" ID/6.5" OD banded with copper wire

-276

6.0" ID/6.25" OD without cage

-2760

6.0" ID/6.25" OD banded with copper wire

-277

7.0" ID/7.25" OD without cage

-2770

7.0" ID/7.25" OD banded with copper wire

-LUC18

0.18 mm ID MXT Column in Lucidity Column Cartridge (fits Lucidity miniGCs)*

-LUC25

0.25 mm ID MXT Column in Lucidity Column Cartridge (fits Lucidity miniGCs)*

-LUC28

0.28 mm ID MXT Column in Lucidity Column Cartridge (fits Lucidity miniGCs)*

-LUC53

0.53 mm ID MXT Column in Lucidity Column Cartridge (fits Lucidity miniGCs)*

All MXT leads are 36" unless otherwise noted.

*MXT columns for Lucidity miniGCs must be ≤30 m long. Each column comes factory connected in a column cartridge (additional cost will be applied).

*Lucidity Column Cartridges not available for MXT-PLOT columns.

If you don't see what you need, email Customer Service for a custom coiled column.